Energy Performance Certificate

34 Potternewton Heights, LS7 3DD

EPC Report

Energy rating

Current: 35 F | Potential: 35 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 35 F Potential: 35 F

Environmental impact (CO₂)

Current: 26 | Potential: 26
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 26 Potential: 26
Field Value
LMK KEY 9020-3408-2297-2622-8141
ADDRESS1 34 Potternewton Heights
ADDRESS2
ADDRESS3
POSTCODE LS7 3DD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 35
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2022-11-28
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001321
COUNTY
LODGEMENT DATE 2023-03-16
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 26
ENERGY CONSUMPTION CURRENT 673
ENERGY CONSUMPTION POTENTIAL 673
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 114
CO2 EMISSIONS POTENTIAL 7.6
LIGHTING COST CURRENT 164
LIGHTING COST POTENTIAL 164
HEATING COST CURRENT 1570
HEATING COST POTENTIAL 1570
HOT WATER COST CURRENT 1511
HOT WATER COST POTENTIAL 1511
TOTAL FLOOR AREA 67
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 1.86 W/m²K
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters, radiators
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 34 Potternewton Heights
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds North East
POSTTOWN LEEDS
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2023-03-16 14:37:58
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 72160224
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000003
Address display
Nation ew