Energy Performance Certificate

32, Beaumont Rd, ME16 8NG

EPC Report

Energy rating

Current: 72 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 70 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 85 Potential: 85
Field Value
LMK KEY 9013-3003-7209-5474-1204
ADDRESS1 32
ADDRESS2 Beaumont Rd
ADDRESS3
POSTCODE ME16 8NG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-01-19
LOCAL AUTHORITY E07000110
CONSTITUENCY E14001349
COUNTY
LODGEMENT DATE 2024-01-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 193
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 91
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 679
HEATING COST POTENTIAL 628
HOT WATER COST CURRENT 179
HOT WATER COST POTENTIAL 120
TOTAL FLOOR AREA 66
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32, Beaumont Rd
LOCAL AUTHORITY LABEL Maidstone
CONSTITUENCY LABEL Maidstone and Malling
POSTTOWN Maidstone
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-01-21 16:08:26
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew