Energy Performance Certificate

31, Bank Crest, Baildon, BD17 5HB

EPC Report

Energy rating

Current: 37 F | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 33 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 75 Potential: 75
Field Value
LMK KEY 9008-9087-7239-1684-5974
ADDRESS1 31, Bank Crest
ADDRESS2 Baildon
ADDRESS3
POSTCODE BD17 5HB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-01-10
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001472
COUNTY
LODGEMENT DATE 2014-01-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 409
ENERGY CONSUMPTION POTENTIAL 130
CO2 EMISSIONS CURRENT 9.1
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 1545
HEATING COST POTENTIAL 744
HOT WATER COST CURRENT 269
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 115
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.74
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Bank Crest, Baildon
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Shipley
POSTTOWN SHIPLEY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-01-19 18:09:24
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100051278674
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew