Energy Performance Certificate

22 Saffron Close, CR0 3GT

EPC Report

Energy rating

Current: 69 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 65 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 74 Potential: 74
Field Value
LMK KEY 9000-3005-0852-0190-7892
ADDRESS1 22 Saffron Close
ADDRESS2
ADDRESS3
POSTCODE CR0 3GT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-10-10
LOCAL AUTHORITY E09000029
CONSTITUENCY E14001153
COUNTY
LODGEMENT DATE 2025-10-12
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 166
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1141
HEATING COST POTENTIAL 906
HOT WATER COST CURRENT 177
HOT WATER COST POTENTIAL 177
TOTAL FLOOR AREA 125
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22 Saffron Close
LOCAL AUTHORITY LABEL Sutton
CONSTITUENCY LABEL Carshalton and Wallington
POSTTOWN CROYDON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2025-10-12 20:54:53
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 5870103980
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew