Energy Performance Certificate
60a, Beacon Hill Road, NG24 1NU
Energy rating
Current: 68 D | Potential: 80 C
Environmental impact (CO₂)
Current: 70
| Potential: 84
| Field | Value |
|---|---|
| LMK KEY | 8992-7728-0090-2096-6902 |
| ADDRESS1 | 60a, Beacon Hill Road |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | NG24 1NU |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 68 |
| POTENTIAL ENERGY EFFICIENCY | 80 |
| PROPERTY TYPE | Flat |
| BUILT FORM | End-Terrace |
| INSPECTION DATE | 2012-08-06 |
| LOCAL AUTHORITY | E07000175 |
| CONSTITUENCY | E14001375 |
| COUNTY | — |
| LODGEMENT DATE | 2012-08-06 |
| TRANSACTION TYPE | rental (private) |
| ENVIRONMENT IMPACT CURRENT | 70 |
| ENVIRONMENT IMPACT POTENTIAL | 84 |
| ENERGY CONSUMPTION CURRENT | 220 |
| ENERGY CONSUMPTION POTENTIAL | 117 |
| CO2 EMISSIONS CURRENT | 2.1 |
| CO2 EMISS CURR PER FLOOR AREA | 42 |
| CO2 EMISSIONS POTENTIAL | 1.1 |
| LIGHTING COST CURRENT | 56 |
| LIGHTING COST POTENTIAL | 31 |
| HEATING COST CURRENT | 406 |
| HEATING COST POTENTIAL | 251 |
| HOT WATER COST CURRENT | 48 |
| HOT WATER COST POTENTIAL | 48 |
| TOTAL FLOOR AREA | 50 |
| ENERGY TARIFF | Unknown |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | 3 |
| FLAT TOP STOREY | Y |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 17 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | (other premises below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Solid brick, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 17% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.42 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 60a, Beacon Hill Road |
| LOCAL AUTHORITY LABEL | Newark and Sherwood |
| CONSTITUENCY LABEL | Newark |
| POSTTOWN | NEWARK |
| CONSTRUCTION AGE BAND | England and Wales: 1900-1929 |
| LODGEMENT DATETIME | 2012-08-06 22:01:22 |
| TENURE | — |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 1 |
| UPRN | 100031438172 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2012.csv |
| COUNTRY | England |
| REGION | E12000004 |
| Address display | — |
| Nation | ew |