Energy Performance Certificate

52, Station Road, KT7 0NS

EPC Report

Energy rating

Current: 58 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 51 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 76 Potential: 76
Field Value
LMK KEY 8982-6424-9030-0737-3992
ADDRESS1 52, Station Road
ADDRESS2
ADDRESS3
POSTCODE KT7 0NS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-04-13
LOCAL AUTHORITY E07000207
CONSTITUENCY E14001230
COUNTY
LODGEMENT DATE 2012-04-13
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 222
ENERGY CONSUMPTION POTENTIAL 105
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 144
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 1302
HEATING COST POTENTIAL 841
HOT WATER COST CURRENT 132
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 190
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 95
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.54
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52, Station Road
LOCAL AUTHORITY LABEL Elmbridge
CONSTITUENCY LABEL Esher and Walton
POSTTOWN THAMES DITTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2012-04-13 16:34:45
TENURE
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100061324383
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000008
Address display