Energy Performance Certificate
68, Phillip Street, CH2 3DA
Energy rating
Current: 16 G | Potential: 84 B
Environmental impact (CO₂)
Current: 29
| Potential: 82
| Field | Value |
|---|---|
| LMK KEY | 8981-6123-9760-2139-7992 |
| ADDRESS1 | 68, Phillip Street |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | CH2 3DA |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | G |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 16 |
| POTENTIAL ENERGY EFFICIENCY | 84 |
| PROPERTY TYPE | House |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2019-07-11 |
| LOCAL AUTHORITY | E06000050 |
| CONSTITUENCY | E14001163 |
| COUNTY | — |
| LODGEMENT DATE | 2019-07-15 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 29 |
| ENVIRONMENT IMPACT POTENTIAL | 82 |
| ENERGY CONSUMPTION CURRENT | 601 |
| ENERGY CONSUMPTION POTENTIAL | 115 |
| CO2 EMISSIONS CURRENT | 6.8 |
| CO2 EMISS CURR PER FLOOR AREA | 102 |
| CO2 EMISSIONS POTENTIAL | 1.4 |
| LIGHTING COST CURRENT | 105 |
| LIGHTING COST POTENTIAL | 53 |
| HEATING COST CURRENT | 1625 |
| HEATING COST POTENTIAL | 442 |
| HOT WATER COST CURRENT | 581 |
| HOT WATER COST POTENTIAL | 48 |
| TOTAL FLOOR AREA | 67 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | None |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 4 |
| NUMBER HEATED ROOMS | 0 |
| LOW ENERGY LIGHTING | 0 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | No system present: electric immersion assumed |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Solid brick, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | No system present: electric heaters assumed |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | None |
| MAINHEATC ENERGY EFF | Very Poor |
| MAINHEATC ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| MAIN FUEL | To be used only when there is no heating/hot-water system or data is from a community network |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.4 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 68, Phillip Street |
| LOCAL AUTHORITY LABEL | Cheshire West and Chester |
| CONSTITUENCY LABEL | Chester North and Neston |
| POSTTOWN | CHESTER |
| CONSTRUCTION AGE BAND | England and Wales: 1900-1929 |
| LODGEMENT DATETIME | 2019-07-15 07:29:44 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| UPRN | 100010024068 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2019.csv |
| COUNTRY | England |
| REGION | E12000002 |
| Address display | — |
| Nation | ew |