Energy Performance Certificate

Flat 21, George House, Primett Road, SG1 3EE

EPC Report

Energy rating

Current: 87 B | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 B Current: 87 B 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 86 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 86 Potential: 86
Field Value
LMK KEY 8976-7239-4479-8839-0992
ADDRESS1 Flat 21
ADDRESS2 George House
ADDRESS3 Primett Road
POSTCODE SG1 3EE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 87
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Flat
BUILT FORM
INSPECTION DATE 2016-11-11
LOCAL AUTHORITY E07000243
CONSTITUENCY E14001516
COUNTY
LODGEMENT DATE 2016-11-11
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 100
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 58
HEATING COST POTENTIAL 58
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 174
TOTAL FLOOR AREA 75
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Air source heat pump , electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 21, George House, Primett Road
LOCAL AUTHORITY LABEL Stevenage
CONSTITUENCY LABEL Stevenage
POSTTOWN STEVENAGE
CONSTRUCTION AGE BAND 2015
LODGEMENT DATETIME 2016-11-11 16:33:42
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10070255349
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew