Energy Performance Certificate

Flat 5 Regency Court, 29, Brunswick Road, SM1 4EH

EPC Report

Energy rating

Current: 53 E | Potential: 56 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 56 D Potential: 56 D

Environmental impact (CO₂)

Current: 36 | Potential: 39
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 39 Potential: 39
Field Value
LMK KEY 8968-7323-4230-8757-6906
ADDRESS1 Flat 5 Regency Court
ADDRESS2 29, Brunswick Road
ADDRESS3
POSTCODE SM1 4EH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 56
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2018-07-03
LOCAL AUTHORITY E09000029
CONSTITUENCY E14001534
COUNTY
LODGEMENT DATE 2019-03-14
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 39
ENERGY CONSUMPTION CURRENT 470
ENERGY CONSUMPTION POTENTIAL 435
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 4.7
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 785
HEATING COST POTENTIAL 711
HOT WATER COST CURRENT 192
HOT WATER COST POTENTIAL 192
TOTAL FLOOR AREA 64
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Warm air, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 8.0
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 5 Regency Court, 29, Brunswick Road
LOCAL AUTHORITY LABEL Sutton
CONSTITUENCY LABEL Sutton and Cheam
POSTTOWN SUTTON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2019-03-14 14:21:21
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 5870037915
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000007
Address display
Nation ew