Energy Performance Certificate

9, Sylvan Close, RH8 0DX

EPC Report

Energy rating

Current: 64 D | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 63 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 68 Potential: 68
Field Value
LMK KEY 8965-7220-4079-1070-3972
ADDRESS1 9, Sylvan Close
ADDRESS2
ADDRESS3
POSTCODE RH8 0DX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-10-30
LOCAL AUTHORITY E07000215
CONSTITUENCY E14001215
COUNTY
LODGEMENT DATE 2015-10-30
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 194
ENERGY CONSUMPTION POTENTIAL 169
CO2 EMISSIONS CURRENT 7.2
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 6.2
LIGHTING COST CURRENT 99
LIGHTING COST POTENTIAL 99
HEATING COST CURRENT 1604
HEATING COST POTENTIAL 1604
HOT WATER COST CURRENT 153
HOT WATER COST POTENTIAL 153
TOTAL FLOOR AREA 227
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, supply and extract
ADDRESS 9, Sylvan Close
LOCAL AUTHORITY LABEL Tandridge
CONSTITUENCY LABEL East Surrey
POSTTOWN OXTED
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-10-30 17:44:29
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 50
LOW ENERGY FIXED LIGHT COUNT 50
UPRN 100061586812
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew