Energy Performance Certificate

4, Helene Grove, DN32 8JX

EPC Report

Energy rating

Current: 22 F | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 32 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 95 Potential: 95
Field Value
LMK KEY 8957-7326-0150-8962-4992
ADDRESS1 4, Helene Grove
ADDRESS2
ADDRESS3
POSTCODE DN32 8JX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-06-12
LOCAL AUTHORITY E06000012
CONSTITUENCY E14001255
COUNTY
LODGEMENT DATE 2013-06-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 642
ENERGY CONSUMPTION POTENTIAL 32
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 114
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 29
HEATING COST CURRENT 719
HEATING COST POTENTIAL 269
HOT WATER COST CURRENT 626
HOT WATER COST POTENTIAL 60
TOTAL FLOOR AREA 48
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Helene Grove
LOCAL AUTHORITY LABEL North East Lincolnshire
CONSTITUENCY LABEL Great Grimsby and Cleethorpes
POSTTOWN GRIMSBY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-06-12 06:54:19
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 11011646
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew