Energy Performance Certificate

Flat 19, Tabernacle Chapel, Garth Road, LL57 2RL

EPC Report

Energy rating

Current: 32 F | Potential: 63 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 63 D Potential: 63 D

Environmental impact (CO₂)

Current: 16 | Potential: 42
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 42 Potential: 42
Field Value
LMK KEY 8955-6827-4520-4595-7902
ADDRESS1 Flat 19
ADDRESS2 Tabernacle Chapel
ADDRESS3 Garth Road
POSTCODE LL57 2RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 63
PROPERTY TYPE Maisonette
BUILT FORM Semi-Detached
INSPECTION DATE 2015-03-05
LOCAL AUTHORITY W06000002
CONSTITUENCY W07000083
COUNTY
LODGEMENT DATE 2015-03-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 42
ENERGY CONSUMPTION CURRENT 837
ENERGY CONSUMPTION POTENTIAL 449
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 141
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 1117
HEATING COST POTENTIAL 494
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 142
TOTAL FLOOR AREA 57
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 10.4
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 19, Tabernacle Chapel, Garth Road
LOCAL AUTHORITY LABEL Gwynedd
CONSTITUENCY LABEL Bangor Aberconwy
POSTTOWN BANGOR
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-03-06 13:23:20
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10070349117
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew