Energy Performance Certificate

Basement Flat, 7 The Elms, SR2 7BZ

EPC Report

Energy rating

Current: 70 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 68 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 83 Potential: 83
Field Value
LMK KEY 8954-7526-2240-6413-7992
ADDRESS1 Basement Flat
ADDRESS2 7 The Elms
ADDRESS3
POSTCODE SR2 7BZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-06-17
LOCAL AUTHORITY E08000024
CONSTITUENCY E14001531
COUNTY
LODGEMENT DATE 2014-06-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 179
ENERGY CONSUMPTION POTENTIAL 97
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 801
HEATING COST POTENTIAL 447
HOT WATER COST CURRENT 73
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 124
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 45
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 45% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.71
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Basement Flat, 7 The Elms
LOCAL AUTHORITY LABEL Sunderland
CONSTITUENCY LABEL Sunderland Central
POSTTOWN SUNDERLAND
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-06-18 14:49:05
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 45056863
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000001
Address display
Nation ew