Energy Performance Certificate

121, Elwick Road, TS26 9BQ

EPC Report

Energy rating

Current: 32 F | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 8 | Potential: 37
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 8 Current: 8 37 Potential: 37
Field Value
LMK KEY 8954-7329-1730-9367-3996
ADDRESS1 121, Elwick Road
ADDRESS2
ADDRESS3
POSTCODE TS26 9BQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-01-13
LOCAL AUTHORITY E06000001
CONSTITUENCY E14001272
COUNTY
LODGEMENT DATE 2014-02-19
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 8
ENVIRONMENT IMPACT POTENTIAL 37
ENERGY CONSUMPTION CURRENT 692
ENERGY CONSUMPTION POTENTIAL 379
CO2 EMISSIONS CURRENT 21
CO2 EMISS CURR PER FLOOR AREA 139
CO2 EMISSIONS POTENTIAL 11
LIGHTING COST CURRENT 132
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 2156
HEATING COST POTENTIAL 1283
HOT WATER COST CURRENT 431
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 150
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 36
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From secondary system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 36% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.19
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 121, Elwick Road
LOCAL AUTHORITY LABEL Hartlepool
CONSTITUENCY LABEL Hartlepool
POSTTOWN HARTLEPOOL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-02-19 15:38:16
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100110010479
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000001
Address display
Nation ew