Energy Performance Certificate

3, Manless Terrace, Skelton-in-Cleveland, TS12 2DQ

EPC Report

Energy rating

Current: 33 F | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 85 | Potential: 102
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 102 Potential: 102
Field Value
LMK KEY 8953-7424-5840-7153-4926
ADDRESS1 3, Manless Terrace
ADDRESS2 Skelton-in-Cleveland
ADDRESS3
POSTCODE TS12 2DQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-04-27
LOCAL AUTHORITY E06000003
CONSTITUENCY E14001368
COUNTY
LODGEMENT DATE 2017-04-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 102
ENERGY CONSUMPTION CURRENT 479
ENERGY CONSUMPTION POTENTIAL 240
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL -0.2
LIGHTING COST CURRENT 107
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1301
HEATING COST POTENTIAL 933
HOT WATER COST CURRENT 323
HOT WATER COST POTENTIAL 122
TOTAL FLOOR AREA 80
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, wood logs
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL wood logs
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.61
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Manless Terrace, Skelton-in-Cleveland
LOCAL AUTHORITY LABEL Redcar and Cleveland
CONSTITUENCY LABEL Middlesbrough South and East Cleveland
POSTTOWN SALTBURN-BY-THE-SEA
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-04-27 14:16:54
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100110083916
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000001
Address display
Nation ew