Energy Performance Certificate
Flat 32 Montagu House, Greenside Road, W12 9DE
Energy rating
Current: 87 B | Potential: 87 B
Environmental impact (CO₂)
Current: 89
| Potential: 89
| Field | Value |
|---|---|
| LMK KEY | 8945-7335-3670-1663-3926 |
| ADDRESS1 | Flat 32 Montagu House |
| ADDRESS2 | Greenside Road |
| ADDRESS3 | — |
| POSTCODE | W12 9DE |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 87 |
| POTENTIAL ENERGY EFFICIENCY | 87 |
| PROPERTY TYPE | Flat |
| BUILT FORM | — |
| INSPECTION DATE | 2015-05-27 |
| LOCAL AUTHORITY | E09000013 |
| CONSTITUENCY | E14001264 |
| COUNTY | — |
| LODGEMENT DATE | 2015-05-27 |
| TRANSACTION TYPE | New dwelling |
| ENVIRONMENT IMPACT CURRENT | 89 |
| ENVIRONMENT IMPACT POTENTIAL | 89 |
| ENERGY CONSUMPTION CURRENT | 64 |
| ENERGY CONSUMPTION POTENTIAL | 64 |
| CO2 EMISSIONS CURRENT | 1.1 |
| CO2 EMISS CURR PER FLOOR AREA | 11 |
| CO2 EMISSIONS POTENTIAL | 1.1 |
| LIGHTING COST CURRENT | 62 |
| LIGHTING COST POTENTIAL | 62 |
| HEATING COST CURRENT | 138 |
| HEATING COST POTENTIAL | 138 |
| HOT WATER COST CURRENT | 126 |
| HOT WATER COST POTENTIAL | 126 |
| TOTAL FLOOR AREA | 105 |
| ENERGY TARIFF | standard tariff |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | 3 |
| FLAT TOP STOREY | Y |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Very Good |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.13 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| WALLS DESCRIPTION | Average thermal transmittance 0.18 W/m²K |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Average thermal transmittance 0.15 W/m²K |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Exhaust air MEV source heat pump, Underfloor heating, pipes in screed above insulation, electric |
| MAINHEAT ENERGY EFF | Very Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | Electricity: electricity, unspecified tariff |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.545 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | Flat 32 Montagu House, Greenside Road |
| LOCAL AUTHORITY LABEL | Hammersmith and Fulham |
| CONSTITUENCY LABEL | Hammersmith and Chiswick |
| POSTTOWN | LONDON |
| CONSTRUCTION AGE BAND | 2015 |
| LODGEMENT DATETIME | 2015-05-27 15:26:26 |
| TENURE | unknown |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 10 |
| UPRN | 34156418 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 3 |
| Source file | certificates-2015.csv |
| COUNTRY | England |
| REGION | E12000007 |
| Address display | — |
| Nation | ew |