Energy Performance Certificate

9, Markstakes Corner, South Chailey, BN8 4BP

EPC Report

Energy rating

Current: 38 F | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 25 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 66 Potential: 66
Field Value
LMK KEY 8944-7925-2960-1367-7922
ADDRESS1 9, Markstakes Corner
ADDRESS2 South Chailey
ADDRESS3
POSTCODE BN8 4BP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-05-23
LOCAL AUTHORITY E07000063
CONSTITUENCY E14001212
COUNTY
LODGEMENT DATE 2014-06-03
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 401
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 104
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 953
HEATING COST POTENTIAL 447
HOT WATER COST CURRENT 288
HOT WATER COST POTENTIAL 121
TOTAL FLOOR AREA 71
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, LPG
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, coal
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.26
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Markstakes Corner, South Chailey
LOCAL AUTHORITY LABEL Lewes
CONSTITUENCY LABEL East Grinstead and Uckfield
POSTTOWN LEWES
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-06-03 12:28:21
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060060180
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display