Energy Performance Certificate

94, Hacking Drive, Longridge, PR3 3FP

EPC Report

Energy rating

Current: 18 G | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 15 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 15 Current: 15 80 Potential: 80
Field Value
LMK KEY 8926-7525-4440-5347-6906
ADDRESS1 94, Hacking Drive
ADDRESS2 Longridge
ADDRESS3
POSTCODE PR3 3FP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2016-05-03
LOCAL AUTHORITY E07000124
CONSTITUENCY E14001443
COUNTY
LODGEMENT DATE 2016-05-06
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 15
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 743
ENERGY CONSUMPTION POTENTIAL 122
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 131
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 2210
HEATING COST POTENTIAL 582
HOT WATER COST CURRENT 356
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 96
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 94, Hacking Drive, Longridge
LOCAL AUTHORITY LABEL Ribble Valley
CONSTITUENCY LABEL Ribble Valley
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-05-06 12:58:14
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100010592381
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew