Energy Performance Certificate

109c Myddleton Road, N22 8NE

EPC Report

Energy rating

Current: 82 B | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 68 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 81 Potential: 81
Field Value
LMK KEY 8921-0057-0423-2008-0473
ADDRESS1 109c Myddleton Road
ADDRESS2
ADDRESS3
POSTCODE N22 8NE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2024-05-02
LOCAL AUTHORITY E09000014
CONSTITUENCY E14001503
COUNTY
LODGEMENT DATE 2024-05-02
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 227
ENERGY CONSUMPTION POTENTIAL 123
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 85
HEATING COST CURRENT 735
HEATING COST POTENTIAL 523
HOT WATER COST CURRENT 367
HOT WATER COST POTENTIAL 154
TOTAL FLOOR AREA 46
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 50
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 109c Myddleton Road
LOCAL AUTHORITY LABEL Haringey
CONSTITUENCY LABEL Southgate and Wood Green
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2024-05-02 16:44:28
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10090478837
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew