Energy Performance Certificate

2 Amersham Road, SE14 6QE

EPC Report

Energy rating

Current: 56 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 46 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 68 Potential: 68
Field Value
LMK KEY 8917-5127-2000-0950-2296
ADDRESS1 2 Amersham Road
ADDRESS2
ADDRESS3
POSTCODE SE14 6QE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2023-03-10
LOCAL AUTHORITY E09000023
CONSTITUENCY E14001332
COUNTY
LODGEMENT DATE 2023-03-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 256
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 7.2
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 214
LIGHTING COST POTENTIAL 214
HEATING COST CURRENT 2962
HEATING COST POTENTIAL 1891
HOT WATER COST CURRENT 295
HOT WATER COST POTENTIAL 264
TOTAL FLOOR AREA 160
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 93
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 93% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 Amersham Road
LOCAL AUTHORITY LABEL Lewisham
CONSTITUENCY LABEL Lewisham North
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2023-03-20 13:13:28
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 100021925817
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew