Energy Performance Certificate

Flat 2, 37 Park Road, CT11 9TL

EPC Report

Energy rating

Current: 49 E | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 55 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 69 Potential: 69
Field Value
LMK KEY 8912-6425-9010-3848-5992
ADDRESS1 Flat 2
ADDRESS2 37 Park Road
ADDRESS3
POSTCODE CT11 9TL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2012-05-18
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001216
COUNTY
LODGEMENT DATE 2012-05-18
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 308
ENERGY CONSUMPTION POTENTIAL 205
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 894
HEATING COST POTENTIAL 626
HOT WATER COST CURRENT 83
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 88
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 15
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 15% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 6.54
FLOOR HEIGHT 2.99
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 2, 37 Park Road
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL East Thanet
POSTTOWN RAMSGATE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-05-18 11:59:44
TENURE
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100062100488
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000008
Address display
Nation ew