Energy Performance Certificate

8, Thirlmere Road, S8 0UN

EPC Report

Energy rating

Current: 48 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 44 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 75 Potential: 75
Field Value
LMK KEY 8909-7971-7329-8307-9643
ADDRESS1 8, Thirlmere Road
ADDRESS2
ADDRESS3
POSTCODE S8 0UN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-06-03
LOCAL AUTHORITY E08000039
CONSTITUENCY E14001467
COUNTY
LODGEMENT DATE 2014-06-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 390
ENERGY CONSUMPTION POTENTIAL 160
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 75
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 894
HEATING COST POTENTIAL 607
HOT WATER COST CURRENT 82
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 61
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 17
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.69
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Thirlmere Road
LOCAL AUTHORITY LABEL Sheffield
CONSTITUENCY LABEL Sheffield Central
POSTTOWN SHEFFIELD
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-06-03 15:13:12
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100051093452
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew