Energy Performance Certificate

5, Croft Close, South Milford, LS25 5FF

EPC Report

Energy rating

Current: 83 B | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 85 | Potential: 96
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 96 Potential: 96
Field Value
LMK KEY 8908-9314-2239-4907-1263
ADDRESS1 5, Croft Close
ADDRESS2 South Milford
ADDRESS3
POSTCODE LS25 5FF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM
INSPECTION DATE 2016-02-09
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001464
COUNTY
LODGEMENT DATE 2016-02-09
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 96
ENERGY CONSUMPTION CURRENT 99
ENERGY CONSUMPTION POTENTIAL 26
CO2 EMISSIONS CURRENT 1.5
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 273
HEATING COST POTENTIAL 273
HOT WATER COST CURRENT 88
HOT WATER COST POTENTIAL 54
TOTAL FLOOR AREA 87
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.26 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 5, Croft Close, South Milford
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Selby
POSTTOWN LEEDS
CONSTRUCTION AGE BAND 2015
LODGEMENT DATETIME 2016-02-09 12:35:42
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10093088715
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew