Energy Performance Certificate

61, Church Road, Wordsley, DY8 5AU

EPC Report

Energy rating

Current: 57 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 51 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 91 Potential: 91
Field Value
LMK KEY 8908-5865-7329-2807-3133
ADDRESS1 61, Church Road
ADDRESS2 Wordsley
ADDRESS3
POSTCODE DY8 5AU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-09-06
LOCAL AUTHORITY E08000027
CONSTITUENCY E14001316
COUNTY
LODGEMENT DATE 2017-09-11
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 364
ENERGY CONSUMPTION POTENTIAL 60
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 650
HEATING COST POTENTIAL 314
HOT WATER COST CURRENT 108
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 58
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 61, Church Road, Wordsley
LOCAL AUTHORITY LABEL Dudley
CONSTITUENCY LABEL Kingswinford and South Staffordshire
POSTTOWN STOURBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-09-11 12:04:00
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 90066880
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display
Nation ew