Energy Performance Certificate

1, Cherwell Drive, Buttershaw, BD6 2BX

EPC Report

Energy rating

Current: 83 B | Potential: 96 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 96 A Potential: 96 A

Environmental impact (CO₂)

Current: 86 | Potential: 99
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 99 Potential: 99
Field Value
LMK KEY 8907-2425-9539-2907-7583
ADDRESS1 1, Cherwell Drive
ADDRESS2 Buttershaw
ADDRESS3
POSTCODE BD6 2BX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 96
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2018-05-02
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001119
COUNTY
LODGEMENT DATE 2018-05-02
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 99
ENERGY CONSUMPTION CURRENT 103
ENERGY CONSUMPTION POTENTIAL 8
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 202
HEATING COST POTENTIAL 202
HOT WATER COST CURRENT 70
HOT WATER COST POTENTIAL 42
TOTAL FLOOR AREA 64
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.13 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.08 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 1, Cherwell Drive, Buttershaw
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Bradford South
POSTTOWN BRADFORD
CONSTRUCTION AGE BAND 2017
LODGEMENT DATETIME 2018-05-02 14:57:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 10023346908
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000003
Address display
Nation ew