Energy Performance Certificate

51, Cromer Road, Finedon, NN9 5LP

EPC Report

Energy rating

Current: 72 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 72 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 79 Potential: 79
Field Value
LMK KEY 8907-1605-2929-9997-0883
ADDRESS1 51, Cromer Road
ADDRESS2 Finedon
ADDRESS3
POSTCODE NN9 5LP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2018-08-10
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001571
COUNTY
LODGEMENT DATE 2018-08-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 197
ENERGY CONSUMPTION POTENTIAL 147
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 35
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 388
HEATING COST POTENTIAL 295
HOT WATER COST CURRENT 79
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 64
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 51, Cromer Road, Finedon
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Wellingborough and Rushden
POSTTOWN WELLINGBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2018-08-10 14:13:15
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100031196453
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000004
Address display
Nation ew