Energy Performance Certificate

Flat 3, 173 City Road, CF24 3JB

EPC Report

Energy rating

Current: 53 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 58 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 60 Potential: 60
Field Value
LMK KEY 8906-8405-8329-3227-0833
ADDRESS1 Flat 3
ADDRESS2 173 City Road
ADDRESS3
POSTCODE CF24 3JB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-08-20
LOCAL AUTHORITY W06000015
CONSTITUENCY W07000089
COUNTY
LODGEMENT DATE 2017-08-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 296
ENERGY CONSUMPTION POTENTIAL 275
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 44
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 632
HEATING COST POTENTIAL 306
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 192
TOTAL FLOOR AREA 56
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 8.35
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 3, 173 City Road
LOCAL AUTHORITY LABEL Cardiff
CONSTITUENCY LABEL Cardiff East
POSTTOWN CARDIFF
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-08-21 08:37:27
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10002525214
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew