Energy Performance Certificate

12, Prescelly Close, RG22 5DN

EPC Report

Energy rating

Current: 49 E | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 42 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 55 Potential: 55
Field Value
LMK KEY 8906-4076-8029-8007-4183
ADDRESS1 12, Prescelly Close
ADDRESS2
ADDRESS3
POSTCODE RG22 5DN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2018-09-03
LOCAL AUTHORITY E07000084
CONSTITUENCY E14001078
COUNTY
LODGEMENT DATE 2018-09-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 386
ENERGY CONSUMPTION POTENTIAL 273
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 1001
HEATING COST POTENTIAL 930
HOT WATER COST CURRENT 103
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 86
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 91
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Prescelly Close
LOCAL AUTHORITY LABEL Basingstoke and Deane
CONSTITUENCY LABEL Basingstoke
POSTTOWN BASINGSTOKE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-09-03 19:35:34
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060239639
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew