Energy Performance Certificate
4, Thamesdale, Whitby, CH65 6QS
Energy rating
Current: 47 E | Potential: 60 D
Environmental impact (CO₂)
Current: 39
| Potential: 49
| Field | Value |
|---|---|
| LMK KEY | 8906-3489-2229-6896-2963 |
| ADDRESS1 | 4, Thamesdale |
| ADDRESS2 | Whitby |
| ADDRESS3 | — |
| POSTCODE | CH65 6QS |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | D |
| CURRENT ENERGY EFFICIENCY | 47 |
| POTENTIAL ENERGY EFFICIENCY | 60 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2016-01-18 |
| LOCAL AUTHORITY | E06000050 |
| CONSTITUENCY | E14001222 |
| COUNTY | — |
| LODGEMENT DATE | 2016-01-20 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 39 |
| ENVIRONMENT IMPACT POTENTIAL | 49 |
| ENERGY CONSUMPTION CURRENT | 380 |
| ENERGY CONSUMPTION POTENTIAL | 293 |
| CO2 EMISSIONS CURRENT | 6.8 |
| CO2 EMISS CURR PER FLOOR AREA | 67 |
| CO2 EMISSIONS POTENTIAL | 5.3 |
| LIGHTING COST CURRENT | 98 |
| LIGHTING COST POTENTIAL | 63 |
| HEATING COST CURRENT | 1306 |
| HEATING COST POTENTIAL | 1245 |
| HOT WATER COST CURRENT | 98 |
| HOT WATER COST POTENTIAL | 64 |
| TOTAL FLOOR AREA | 102 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 6 |
| NUMBER HEATED ROOMS | 6 |
| LOW ENERGY LIGHTING | 45 |
| NUMBER OPEN FIREPLACES | 1 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Solid brick, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 270 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 45% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.62 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 4, Thamesdale, Whitby |
| LOCAL AUTHORITY LABEL | Cheshire West and Chester |
| CONSTITUENCY LABEL | Ellesmere Port and Bromborough |
| POSTTOWN | ELLESMERE PORT |
| CONSTRUCTION AGE BAND | England and Wales: 1900-1929 |
| LODGEMENT DATETIME | 2016-01-20 16:39:03 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| UPRN | 100010126352 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2016.csv |
| COUNTRY | England |
| REGION | E12000002 |
| Address display | — |
| Nation | ew |