Energy Performance Certificate

17, Holly Close, Highmoor Cross, RG9 5DY

EPC Report

Energy rating

Current: 34 F | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 26 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 64 Potential: 64
Field Value
LMK KEY 8904-9672-7329-1927-7543
ADDRESS1 17, Holly Close
ADDRESS2 Highmoor Cross
ADDRESS3
POSTCODE RG9 5DY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2014-05-23
LOCAL AUTHORITY E07000179
CONSTITUENCY E14001280
COUNTY
LODGEMENT DATE 2014-05-26
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 448
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 6.8
CO2 EMISS CURR PER FLOOR AREA 113
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 1186
HEATING COST POTENTIAL 651
HOT WATER COST CURRENT 231
HOT WATER COST POTENTIAL 98
TOTAL FLOOR AREA 60
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17, Holly Close, Highmoor Cross
LOCAL AUTHORITY LABEL South Oxfordshire
CONSTITUENCY LABEL Henley and Thame
POSTTOWN HENLEY-ON-THAMES
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-05-26 14:43:38
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100120864665
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew