Energy Performance Certificate

50, Denmark Close, NN18 9EH

EPC Report

Energy rating

Current: 87 B | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 B Current: 87 B 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 86 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 93 Potential: 93
Field Value
LMK KEY 8903-4792-8029-1497-8743
ADDRESS1 50, Denmark Close
ADDRESS2
ADDRESS3
POSTCODE NN18 9EH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 87
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-03-11
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001179
COUNTY
LODGEMENT DATE 2014-03-11
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 74
ENERGY CONSUMPTION POTENTIAL 32
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 543
HEATING COST POTENTIAL 466
HOT WATER COST CURRENT 98
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 50, Denmark Close
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Corby and East Northamptonshire
POSTTOWN CORBY
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2014-03-11 21:42:15
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100030980418
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000004
Address display
Nation ew