Energy Performance Certificate

34, Chestnut Road, TW2 5QZ

EPC Report

Energy rating

Current: 24 F | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 F Current: 24 F 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 25 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 80 Potential: 80
Field Value
LMK KEY 8902-9153-7929-0127-7153
ADDRESS1 34, Chestnut Road
ADDRESS2
ADDRESS3
POSTCODE TW2 5QZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 24
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-09-25
LOCAL AUTHORITY E09000027
CONSTITUENCY E14001556
COUNTY
LODGEMENT DATE 2015-09-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 614
ENERGY CONSUMPTION POTENTIAL 111
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 107
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 39
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 1086
HEATING COST POTENTIAL 454
HOT WATER COST CURRENT 346
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 57
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.58
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34, Chestnut Road
LOCAL AUTHORITY LABEL Richmond upon Thames
CONSTITUENCY LABEL Twickenham
POSTTOWN TWICKENHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-09-25 22:15:02
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100022331698
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew