Energy Performance Certificate

7, Tudor Close, SS9 5AR

EPC Report

Energy rating

Current: 71 C | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 69 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 84 Potential: 84
Field Value
LMK KEY 8901-5755-8329-5907-0133
ADDRESS1 7, Tudor Close
ADDRESS2
ADDRESS3
POSTCODE SS9 5AR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-09-05
LOCAL AUTHORITY E06000033
CONSTITUENCY E14001502
COUNTY
LODGEMENT DATE 2017-09-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 185
ENERGY CONSUMPTION POTENTIAL 77
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 108
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 429
HEATING COST POTENTIAL 403
HOT WATER COST CURRENT 139
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 13
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 13% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Tudor Close
LOCAL AUTHORITY LABEL Southend-on-Sea
CONSTITUENCY LABEL Southend West and Leigh
POSTTOWN LEIGH-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2017-09-05 13:11:35
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100090674169
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew