Energy Performance Certificate

77, Cayley Way, PL5 2UA

EPC Report

Energy rating

Current: 64 D | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 61 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 93 Potential: 93
Field Value
LMK KEY 8901-2843-2229-8507-3253
ADDRESS1 77, Cayley Way
ADDRESS2
ADDRESS3
POSTCODE PL5 2UA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-02-04
LOCAL AUTHORITY E06000026
CONSTITUENCY E14001426
COUNTY
LODGEMENT DATE 2015-02-04
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 271
ENERGY CONSUMPTION POTENTIAL 22
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 36
HEATING COST CURRENT 471
HEATING COST POTENTIAL 277
HOT WATER COST CURRENT 82
HOT WATER COST POTENTIAL 55
TOTAL FLOOR AREA 53
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 77, Cayley Way
LOCAL AUTHORITY LABEL Plymouth
CONSTITUENCY LABEL Plymouth Moor View
POSTTOWN PLYMOUTH
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2015-02-04 17:11:08
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100040421280
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew