Energy Performance Certificate

4 Macarthur Close, Bridgerule, EX22 7FQ

EPC Report

Energy rating

Current: 92 A | Potential: 104 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 A Current: 92 A 104 A Potential: 104 A

Environmental impact (CO₂)

Current: 93 | Potential: 103
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 93 Current: 93 103 Potential: 103
Field Value
LMK KEY 8900-5293-0432-1098-3253
ADDRESS1 4 Macarthur Close
ADDRESS2 Bridgerule
ADDRESS3
POSTCODE EX22 7FQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 92
POTENTIAL ENERGY EFFICIENCY 104
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-02-11
LOCAL AUTHORITY E07000046
CONSTITUENCY E14001552
COUNTY
LODGEMENT DATE 2025-02-11
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 93
ENVIRONMENT IMPACT POTENTIAL 103
ENERGY CONSUMPTION CURRENT 30
ENERGY CONSUMPTION POTENTIAL -27
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 5
CO2 EMISSIONS POTENTIAL -1.0
LIGHTING COST CURRENT 148
LIGHTING COST POTENTIAL 148
HEATING COST CURRENT 745
HEATING COST POTENTIAL 746
HOT WATER COST CURRENT 304
HOT WATER COST POTENTIAL 190
TOTAL FLOOR AREA 219
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.25 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 4 Macarthur Close, Bridgerule
LOCAL AUTHORITY LABEL Torridge
CONSTITUENCY LABEL Torridge and Tavistock
POSTTOWN Holsworthy
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2025-02-11 16:32:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 10095917949
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew