Energy Performance Certificate

1, Ebenezer Street, SA38 9BS

EPC Report

Energy rating

Current: 32 F | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 17 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 49 Potential: 49
Field Value
LMK KEY 8900-3154-2629-7506-8933
ADDRESS1 1, Ebenezer Street
ADDRESS2
ADDRESS3
POSTCODE SA38 9BS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2017-01-05
LOCAL AUTHORITY W06000010
CONSTITUENCY W07000087
COUNTY
LODGEMENT DATE 2017-01-05
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 681
ENERGY CONSUMPTION POTENTIAL 307
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 118
CO2 EMISSIONS POTENTIAL 6.1
LIGHTING COST CURRENT 154
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 1487
HEATING COST POTENTIAL 876
HOT WATER COST CURRENT 724
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 116
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.24
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Ebenezer Street
LOCAL AUTHORITY LABEL Carmarthenshire
CONSTITUENCY LABEL Caerfyrddin
POSTTOWN NEWCASTLE EMLYN
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-01-05 15:08:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100100147351
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew