Energy Performance Certificate

41, Heathside, Huntington, YO32 9AA

EPC Report

Energy rating

Current: 84 B | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 85 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 94 Potential: 94
Field Value
LMK KEY 8896-7635-4940-9446-8996
ADDRESS1 41, Heathside
ADDRESS2 Huntington
ADDRESS3
POSTCODE YO32 9AA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-05-16
LOCAL AUTHORITY E06000014
CONSTITUENCY E14001605
COUNTY
LODGEMENT DATE 2016-05-16
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 92
ENERGY CONSUMPTION POTENTIAL 32
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 16
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 306
HEATING COST POTENTIAL 307
HOT WATER COST CURRENT 108
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 112
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.27 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 41, Heathside, Huntington
LOCAL AUTHORITY LABEL York
CONSTITUENCY LABEL York Outer
POSTTOWN YORK
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2016-05-16 08:54:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 10034771477
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew