Energy Performance Certificate

3, Creasy Close, WD5 0HS

EPC Report

Energy rating

Current: 72 C | Potential: 122 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 122 A Potential: 122 A

Environmental impact (CO₂)

Current: 73 | Potential: 119
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 119 Potential: 119
Field Value
LMK KEY 8885-7624-2210-9666-9992
ADDRESS1 3, Creasy Close
ADDRESS2
ADDRESS3
POSTCODE WD5 0HS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 122
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-04-16
LOCAL AUTHORITY E07000102
CONSTITUENCY E14001496
COUNTY
LODGEMENT DATE 2015-06-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 119
ENERGY CONSUMPTION CURRENT 205
ENERGY CONSUMPTION POTENTIAL -181
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL -1.5
LIGHTING COST CURRENT 38
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 322
HEATING COST POTENTIAL 281
HOT WATER COST CURRENT 125
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 50
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Creasy Close
LOCAL AUTHORITY LABEL Three Rivers
CONSTITUENCY LABEL South West Hertfordshire
POSTTOWN ABBOTS LANGLEY
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2015-06-01 15:44:25
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 200000937199
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew