Energy Performance Certificate

2, Longmeade, DA12 2NX

EPC Report

Energy rating

Current: 55 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 52 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 81 Potential: 81
Field Value
LMK KEY 8874-7320-2549-8659-6926
ADDRESS1 2, Longmeade
ADDRESS2
ADDRESS3
POSTCODE DA12 2NX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-10-21
LOCAL AUTHORITY E07000109
CONSTITUENCY E14001254
COUNTY
LODGEMENT DATE 2014-10-26
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 252
ENERGY CONSUMPTION POTENTIAL 87
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 957
HEATING COST POTENTIAL 603
HOT WATER COST CURRENT 205
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 109
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 36
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 36% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Longmeade
LOCAL AUTHORITY LABEL Gravesham
CONSTITUENCY LABEL Gravesham
POSTTOWN GRAVESEND
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2014-10-26 09:15:52
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10012012303
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew