Energy Performance Certificate

53, Sadlers Court, OX14 2PA

EPC Report

Energy rating

Current: 74 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 75 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 80 Potential: 80
Field Value
LMK KEY 8858-7121-6440-6043-7906
ADDRESS1 53, Sadlers Court
ADDRESS2
ADDRESS3
POSTCODE OX14 2PA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2018-09-07
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001420
COUNTY
LODGEMENT DATE 2018-09-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 175
ENERGY CONSUMPTION POTENTIAL 145
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 304
HEATING COST POTENTIAL 260
HOT WATER COST CURRENT 83
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 58
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 53, Sadlers Court
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Oxford West and Abingdon
POSTTOWN ABINGDON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2018-09-10 08:33:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100120910115
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew