Energy Performance Certificate

3, Rectory Field, Chelmondiston, IP9 1HY

EPC Report

Energy rating

Current: 45 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 38 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 64 Potential: 64
Field Value
LMK KEY 8846-7620-2819-7248-7922
ADDRESS1 3, Rectory Field
ADDRESS2 Chelmondiston
ADDRESS3
POSTCODE IP9 1HY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-10-28
LOCAL AUTHORITY E07000200
CONSTITUENCY E14001494
COUNTY
LODGEMENT DATE 2016-11-14
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 239
ENERGY CONSUMPTION POTENTIAL 113
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 176
LIGHTING COST POTENTIAL 88
HEATING COST CURRENT 1409
HEATING COST POTENTIAL 929
HOT WATER COST CURRENT 201
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 176
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Rectory Field, Chelmondiston
LOCAL AUTHORITY LABEL Babergh
CONSTITUENCY LABEL South Suffolk
POSTTOWN IPSWICH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-11-14 21:06:55
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100091003846
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew