Energy Performance Certificate

9, High Street, Welford, NN6 6HT

EPC Report

Energy rating

Current: 24 F | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 F Current: 24 F 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 34 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 90 Potential: 90
Field Value
LMK KEY 8846-6722-5220-2733-8992
ADDRESS1 9, High Street
ADDRESS2 Welford
ADDRESS3
POSTCODE NN6 6HT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 24
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-02-17
LOCAL AUTHORITY E06000062
CONSTITUENCY E14001192
COUNTY
LODGEMENT DATE 2016-02-19
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 555
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 1889
HEATING COST POTENTIAL 871
HOT WATER COST CURRENT 182
HOT WATER COST POTENTIAL 126
TOTAL FLOOR AREA 86
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric, Electric underfloor heating
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.24
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, High Street, Welford
LOCAL AUTHORITY LABEL West Northamptonshire
CONSTITUENCY LABEL Daventry
POSTTOWN NORTHAMPTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-02-19 10:14:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 32
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 28021795
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew