Energy Performance Certificate

4, Percy Road, CH4 7EZ

EPC Report

Energy rating

Current: 34 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 14 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 Current: 14 65 Potential: 65
Field Value
LMK KEY 8844-6327-9700-9185-5926
ADDRESS1 4, Percy Road
ADDRESS2
ADDRESS3
POSTCODE CH4 7EZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-03-25
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001164
COUNTY
LODGEMENT DATE 2014-03-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 14
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 736
ENERGY CONSUMPTION POTENTIAL 215
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 130
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1465
HEATING COST POTENTIAL 504
HOT WATER COST CURRENT 191
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 93
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Percy Road
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Chester South and Eddisbury
POSTTOWN CHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-03-25 16:32:45
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100010023956
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew