Energy Performance Certificate

120, Dargate Road, Yorkletts, CT5 3AG

EPC Report

Energy rating

Current: 70 C | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 58 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 90 Potential: 90
Field Value
LMK KEY 8835-7522-4939-6170-2976
ADDRESS1 120, Dargate Road
ADDRESS2 Yorkletts
ADDRESS3
POSTCODE CT5 3AG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-12-30
LOCAL AUTHORITY E07000106
CONSTITUENCY E14001151
COUNTY
LODGEMENT DATE 2015-12-30
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 209
ENERGY CONSUMPTION POTENTIAL 27
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 942
HEATING COST POTENTIAL 463
HOT WATER COST CURRENT 122
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 86
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 45
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 9
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 9% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.52
PHOTO SUPPLY 40
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 120, Dargate Road, Yorkletts
LOCAL AUTHORITY LABEL Canterbury
CONSTITUENCY LABEL Canterbury
POSTTOWN WHITSTABLE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-12-30 13:43:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100060843134
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew