Energy Performance Certificate

46 HILBRE BANK, ALPRAHAM, CW6 9JG

EPC Report

Energy rating

Current: 37 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 15 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 15 Current: 15 55 Potential: 55
Field Value
LMK KEY 8830-8820-6009-0231-0296
ADDRESS1 46 HILBRE BANK
ADDRESS2 ALPRAHAM
ADDRESS3
POSTCODE CW6 9JG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-10-19
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001164
COUNTY
LODGEMENT DATE 2020-10-20
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 15
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 675
ENERGY CONSUMPTION POTENTIAL 256
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 133
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 1464
HEATING COST POTENTIAL 681
HOT WATER COST CURRENT 478
HOT WATER COST POTENTIAL 123
TOTAL FLOOR AREA 87
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 58
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 58% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 46 HILBRE BANK, ALPRAHAM
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Chester South and Eddisbury
POSTTOWN ALPRAHAM
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2020-10-20 14:33:44
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 200000649815
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew