Energy Performance Certificate

52, Couchman Road, B8 3SP

EPC Report

Energy rating

Current: 52 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 42 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 61 Potential: 61
Field Value
LMK KEY 8825-7722-3439-8265-8992
ADDRESS1 52, Couchman Road
ADDRESS2
ADDRESS3
POSTCODE B8 3SP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-12-15
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001096
COUNTY
LODGEMENT DATE 2015-12-15
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 307
ENERGY CONSUMPTION POTENTIAL 192
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 54
CO2 EMISSIONS POTENTIAL 6.8
LIGHTING COST CURRENT 122
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 2035
HEATING COST POTENTIAL 1440
HOT WATER COST CURRENT 116
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 199
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 12
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.58
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52, Couchman Road
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Ladywood
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-12-15 13:46:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100070336665
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000005
Address display
Nation ew