Energy Performance Certificate

75 PARK ROAD, BINGLEY, BD16 4BP

EPC Report

Energy rating

Current: 48 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 39 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 70 Potential: 70
Field Value
LMK KEY 8819-4127-2000-0198-5296
ADDRESS1 75 PARK ROAD
ADDRESS2 BINGLEY
ADDRESS3
POSTCODE BD16 4BP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-03-18
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001472
COUNTY
LODGEMENT DATE 2021-03-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 373
ENERGY CONSUMPTION POTENTIAL 174
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 5.2
LIGHTING COST CURRENT 102
LIGHTING COST POTENTIAL 102
HEATING COST CURRENT 1911
HEATING COST POTENTIAL 1096
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 159
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 75 PARK ROAD, BINGLEY
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Shipley
POSTTOWN BINGLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-03-18 17:13:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 100051124813
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000003
Address display
Nation ew