Energy Performance Certificate

25, Foxton Gardens, Morley, LS27 0UB

EPC Report

Energy rating

Current: 80 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 80 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 86 Potential: 86
Field Value
LMK KEY 8817-7422-0199-9730-5922
ADDRESS1 25, Foxton Gardens
ADDRESS2 Morley
ADDRESS3
POSTCODE LS27 0UB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-12-20
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001324
COUNTY
LODGEMENT DATE 2013-12-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 120
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 464
HEATING COST POTENTIAL 435
HOT WATER COST CURRENT 134
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, extract only
ADDRESS 25, Foxton Gardens, Morley
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds South West and Morley
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2013-12-22 15:34:37
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 72506708
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew