Energy Performance Certificate

Roadley, Market Rasen Road, Holton-le-Moor, LN7 6AE

EPC Report

Energy rating

Current: 18 G | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 11 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 Current: 11 78 Potential: 78
Field Value
LMK KEY 8816-7425-4290-6447-0902
ADDRESS1 Roadley
ADDRESS2 Market Rasen Road
ADDRESS3 Holton-le-Moor
POSTCODE LN7 6AE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE Bungalow
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-05-03
LOCAL AUTHORITY E07000142
CONSTITUENCY E14001243
COUNTY
LODGEMENT DATE 2016-05-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 11
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 1306
ENERGY CONSUMPTION POTENTIAL 227
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 221
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 31
LIGHTING COST POTENTIAL 31
HEATING COST CURRENT 993
HEATING COST POTENTIAL 297
HOT WATER COST CURRENT 613
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 38
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 10
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Roadley, Market Rasen Road, Holton-le-Moor
LOCAL AUTHORITY LABEL West Lindsey
CONSTITUENCY LABEL Gainsborough
POSTTOWN MARKET RASEN
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-05-03 15:49:31
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10034685447
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew