Energy Performance Certificate

8, Cliffden Close, TQ14 8TU

EPC Report

Energy rating

Current: 68 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 64 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 75 Potential: 75
Field Value
LMK KEY 8814-6524-6400-8470-3972
ADDRESS1 8, Cliffden Close
ADDRESS2
ADDRESS3
POSTCODE TQ14 8TU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-04-30
LOCAL AUTHORITY E07000045
CONSTITUENCY E14001381
COUNTY
LODGEMENT DATE 2014-04-30
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 154
ENERGY CONSUMPTION POTENTIAL 98
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 881
HEATING COST POTENTIAL 768
HOT WATER COST CURRENT 126
HOT WATER COST POTENTIAL 126
TOTAL FLOOR AREA 171
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 26
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 26% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Cliffden Close
LOCAL AUTHORITY LABEL Teignbridge
CONSTITUENCY LABEL Newton Abbot
POSTTOWN TEIGNMOUTH
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2014-04-30 13:44:28
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 31
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100040340271
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display
Nation ew